Table 8—Exterior Masonry Chimney Fan + Nat Installations

with Type--B Double Wall Vent Connectors ENFPA & AGA

Combined Appliance Maximum Input

Rating in Thousands of Btuh per Hour

VENT HEIGHT

FT. (M)

INTERNAL AREA OF CHIMNEY

SQ. IN. (SQ. MM)

12

(7741)

19

(12258)

28

(18064)

38

(24516)

6 (1.8)

74

119

178

257

8 (2.4)

80

130

193

279

10 (3.0)

84

138

207

299

15 (4.5)

NR

152

233

334

20 (6.0)

NR

NR

250

368

30 (9.1)

NR

NR

NR

404

Table 9—Minimum Allowable Input Rating of Space--Heat-

ing Appliance in Thousands of Btuh per Hour

VENT HEIGHT

FT. (M)

INTERNAL AREA OF CHIMNEY

SQ. IN. (SQ. MM)

12

(7741)

19

(12258)

28

18064)

38

(24516)

Local 99% Winter Design Temperature: 17 to 26 degrees F

6

0

55

99

141

8

52

74

111

154

10

NR

90

125

169

15

NR

NR

167

212

20

NR

NR

212

258

30

NR

NR

NR

362

Local 99% Winter Design Temperature: 5 to 16 degrees F*

6

NR

78

121

166

8

NR

94

135

182

10

NR

111

149

198

15

NR

NR

193

247

20

NR

NR

NR

293

30

NR

NR

NR

377

Local 99% Winter Design Temperature: ---10 to 4 degrees F*

6

NR

NR

145

196

8

NR

NR

159

213

10

NR

NR

175

231

15

NR

NR

NR

283

20

NR

NR

NR

333

30

NR

NR

NR

NR

Local 99% Winter Design Temperature: ---11

_

F (16_C)

or

lower

Not recommended for any vent configuration.

*The 99.6% heating db temperatures found in the 1997 or 2001 ASHRAE

Fundamentals Handbook, Climatic Design Information chapter, Table 1A

(United States) or the 2005 ASHRAE Fundamentals handbook, Climatic

Design Information chapter, and the CD---ROM included with the 2005

ASHRAE Fundamentals Handbook.

310AA