beautypg.com

JUMO 707020 dTRANS T02 - Four-Wire Transmitter Data Sheet User Manual

Page 6

background image

2014-08-08/00379095

Data Sheet 707020

JUMO GmbH & Co. KG • 36035 Fulda, Germany

Page 6/12

Analog outputs

Digital outputs (only for types 707021/... and 707022/...)

Current output

Output range

proportional DC current 0 — 20mA or 4 — 20mA programmable

Accuracy

± 0.015mA

Linearity error

± 0.005mA

Max. burden

750

Burden error

± 0.01mA

Ripple

± 1% referred to 20mA, 0 — 90kHz; above 90kHz: tested to EN 50081

Output current on probe break,
over/underrange

0mA or 22mA (programmable)

Voltage output

Output range

0 — 10V or 2 — 10V

Accuracy

± 5mV

Linearity error

± 2mV

Load resistance

 2k

Burden error

± 15mV

Ripple

± 1% referred to 10V, 0 — 90kHz

Output voltage on probe break,
over/underrange

0V or 11V (programmable)

2 open-collector outputs

Output 1

lk7 or lk8 or fault output

Output 2

lk7 or lk8 or frequency output

Function lk7

Function lk8

Switching capacity of open-collector

35V, 100mA

Voltage drop

in switched condition

 1.2V

Short-circuit strength

not available

Frequency output

Function

the frequency output produces the latest measurement as a frequency;

the frequency at range start/end is programmable

Smallest / highest frequency

10Hz / 1000Hz

Error output

Activation

due to probe break, over/underrange and

internal errors (Pt100 of cold junction faulty, EEPROM does not respond)