7 Troubleshooting

What is happening?

Cause / Remedy

Information

Green power LED does
not light up

- Voltage supply to control section not

connected

v Chapter 4 „Electrical

connection“

IPC is not producing any
output power although
green power LED is lit
and a setpoint value set.

- Voltage supply to power section not

connected

v Chapter 4.1 „Screw

connections in the
power section“

- Analog control input not connected

correctly

v Chapter 4.1.4

„Wiring of the screw
terminals“

- Switch positions for control input S 101/8

and 9 set incorrectly

v Chapter 5.5 „Control

inputs“

h Check switch for firing pulse inhibit

S 105

v Chapter 5.6 „Firing

pulse inhibit“

- Load break

- Load short circuit (current-limit LED is lit)

h Check load and load connections

IPC is not producing any
output power although
green power LED is lit, a
setpoint value is set and
the load fail LED is lit.

- Load break

- Load short circuit (current-limit LED is lit

at the same time)

h Check load and load connections
- Safety cut-out in the power section

v Chapter 5.12.2

„Safety cut-out in
the power section“

IPC is not producing any
output power although
green power LED is lit, a
setpoint value is set and
the overheat LED is lit.

- Overtemperature disconnection

v Chapter 3.3

„Ambient
conditions“

IPC does not produce
full power, although
setpoint is set to 100%

- Switch positions for control input S 101/8

and 9 set incorrectly

v Chapter 5.5 „Control

inputs“

- Control input (max. Power adjust) is not

turned clockwise to the stop

h Check adjustment

v Chapter 5.9 „Control

input adjustment
(max. Power adjust)“

- Current limiting active (when the red

current-limit LED is lit)

h Turn the „max. current adjust“ trimmer

clockwise

v Chapter 5.11

„Setting the current
limit (max. current
adjust)“

- Process-dependent power limiting active

h Check switch S 101/10

v Chapter 5.2 „Setting

switches and
jumpers“

h Check switch S 103
h Check switch S 101/7