beautypg.com

5 choke data, 6 emc filter, Choke data – JUMO 709050 IPC IGBT Power Converter IPC 70A Operating Manual User Manual

Page 41: Emc filter, 6 technical data, 5 choke data 6.6 emc filter

background image

02.08 [IGBT Power Converter 70A]

41

6 Technical data

6.5 Choke data

6.6 EMC filter

Type:

Dimensions

Connection
cross
section

Connection,
Tightening torque

Weight

Sales
No.

L = 0.6 mH / I

N

= 75A

protection rating IP 10 as per
EN 60529

Choke diameter: 155 mm
Height: 135 mm
Diameter of fixing
hole: 10.4 mm

4...25 mm

2

Via screw terminals,
max. 4...4.5 Nm

approx.
7.5 kgs

70/00392474

For voltage supply to power section

Nominal voltage,
Nominal current

Dimensions
(length x width x
height)

Connection
cross-section

Tightening
torque

Weight

Permissible
ambient
temperature

Sales
No.

115V/250V/440V AC,
I

Nom

= 16A

(255 x 60 x 130) mm

0.25...4 mm

2

0.6 ... 0.8 Nm

approx. 4
kgs

40°C

70/00399527

115V/250V/440V AC,
I

Nom

= 20A

(289 x 70 x 140) mm

0.5...10 mm

2

1.5 ... 1.8 Nm

approx. 5.5
kgs

40°C

70/00438775

115V/250V/440V AC,
I

Nom

= 32A

(324 x 90 x 160) mm

0.5...10 mm

2

1.5 ... 1.8 Nm

approx. 9.5
kgs

40°C

70/00409831

115V/250V/440V AC,
I

Nom

= 63A

(380 x 117 x 190) mm

0.5...16 mm

2

2 ... 2.3 Nm

approx. 17
kgs

40°C

70/00409990

For voltage supply to the control section

115V/250V AC,
I

Nom

= 1A

(80 x 45 x 30) mm

via
tab connector

6.3 x 0.8mm

-

approx. 120
g

40°C

70/00413620