beautypg.com

5 settings – JUMO 709050 IPC IGBT Power Converter IPC 70A Operating Manual User Manual

Page 31

background image

02.08 [IGBT Power Converter 70A]

31

5 Settings

5.5.1

Combination of external potentiometer and electronic controller

Controller with
current output

The voltage input (terminals 3, 4) in conjunction with the internal 10 V source
and a 5 k

Ω potentiometer is used as a manual control input.

Controller with
voltage output

Only the voltage input of the converter is used. Manual operation requires a 5
k

Ω potentiometer connected to terminals 3 and 5.

Switch

S

a

S

b

Automatic mode

open

open

Manual mode

closed

closed

H

To prevent unintended oversteering when switching over to the
manual mode, S

a

should be mechanically linked to S

b

. Otherwise

both signals will briefly cumulate.

Switch

S

ca

Automatic mode

Position 1

Manual mode

Position 2