E

Setting

Display

Setting

Pre-

range

setting

Analogue output (Output)

MAMP/

VOLT

"MAMP": The analogue output supplies

VOLT

a 4..20 mA signal.

"VOLT":

The analogue output supplies

a 0..10 V signal

Hidden basic settings menu

YES/NO

NO

(Hide)

"YES":

The basic settings menu is

hidden and can only be

accessed if the keys for calling

up the menu are held down

when the supply voltage is

switched on.

Version number (Version)

Display of the current software version

(for reference only)

To end basic settings (End)

YES/NO

NO

8. Programming enable

The unit has 2 types of programming enable which must both be set to "ON" to

change the settings. The software programming enable can be set or removed

during operation. It provides protection from unintentional alteration.

A programming disable via the hardware programming enable means that no

change to the settings can be carried out during operation. This serves, for

example, as a safety function or as protection against unauthorised alterations.

8.1. ALTERING THE SOFTWARE PROGRAMMING ENABLE

! Æ

3 s

" Æ

B

H

G

B

H

press both keys

simultaneously and

hold down for 3s

display

alter setting using individual key:

ON = programming possible

OFF = programming disabled

pressure

display