Example: display of text no. 5, Example: flashing display of text no. 5 – EUCHNER HBAS User Manual
Page 28
EUCHNER
Hand-Held Pendant Station
092491-07-01/09
Subject to technical modifications
Page 28 / 34
Command
byte
Description Parameters
48H
Definition of an item
of text
Text number (
31H...F9H
),
Font size (
50H
or
51H
),
Line (see table below),
Column (see table below),
Text: (
21H...2C
),(
40H...43H
), (
80H...FFH
)
49H
Output of a previously
defined item of text
Text number (
31H...F9H
)
Important!
The line and column information is dependent on the font size!
Font size
Line
Column
small
30H ... 37H
30H ... 3FH
large
30H ... 33H
30H ... 37H
Example:
Definition
of text "
Euchner
" with small font in
line 4 column 0
as text No. 5
The sequence for text and character sent must be observed
Control
system
STX
6CH
48H
35H 50H
34H 30H
A5H
D5H
C3H
C8H
CEH C5H D2H
ETX BCC
HBAS
DLE
DLE
Example:
Display
of text No. 5
Control
system
STX
6CH
49H
35H
ETX BCC
HBAS
DLE
DLE
Example:
Flashing
display
of text No. 5
Control
system
STX
6CH
42H
49H
35H
43H
ETX BCC
HBAS
DLE
DLE
Example:
Definition
of "Clear display" and text "
EUCO
" with small font, inverse display,
at
the start of the display
as text No. 6
Control
system
STX
6CH
48H
36H 50H
30H 30H
2BH
40H
A5H
B5H
A3H
AFH
41H
ETX BCC
HBAS
DLE
DLE