Operating Instructions Safety Switch

CET.-AS-...-CB-...

9

Closing safety guard and activating guard locking

The safety door can be opened as long as the lift tappet is held in the extended

position. Switching the guard locking solenoid on via AS-Interface output bit D0

releases the lift tappet. The actuator's guard locking pin can now press the lift tap-

pet down. The safety door is locked and the solenoid monitoring contact is closed

as soon as the guard locking pin is fully inserted into the recess. The complete

safety code sequence is sent via AS-Interface input bits D0 to D3.

Deactivating guard locking

Switching the guard locking solenoid off via AS-Interface output bit D0 extends the

lift tappet and raises the actuator's guard locking pin over the edge of the recess.

The half-sequence is sent via AS-Interface input bits D0 and D1 in every bus cycle.

Opening safety guard

Opening the safety door moves the actuator out of the operating distance. The

values 0, 0, 0, 0 are continuously sent via AS-Interface input bits D0 to D3.