beautypg.com

Setup, Led indicators, Initial setup – EUCHNER CETx-AS-xxx-CB-xxx (Multicode) User Manual

Page 19: Setup 19 led indicators

background image

Operating Instructions Safety Switch

CET.-AS-...-CB-...

19

Setup

LED indicators

LED

Color

State

Significance

STATE

green

illumi-

nated

Normal operation

(further signal functions see System status table

page 21)

flashing

ASi

red/green

Status messages see chapter AS-Interface status messages page 18

STATE

red

illumi-

nated

Internal electronics fault

LED 1

red

freely configurable*

LED 2

green

freely configurable*

*)

Can vary depending on version. See data sheet.

Initial setup

1. Apply operating voltage to the safety switch.

¨

The green LED flashes cyclically one time and signals that it is in standby

state.

2. Move actuator to the read head (observe distance < S

ao

).

¨

The green LED illuminates continuously and indicates the detection of the

actuator.

LED1 /

(rot/red)

LED 2

OUT D

(grün/green)

ASI

(grün/rot

green/red)

STATE

(grün/rot

green/red)