Status table – EUCHNER CETx-AS-xxx-CB-xxx (Multicode) User Manual
Page 7
Operating Instructions Safety Switch
CET.-AS-...-CB-...
7
Status table
Programming
State
D0, D1
D2, D3
Monitor diagnosis
Dual-channel
conditionally
dependent
Safety guard closed, guard locking
active
Code sequence
Green
Guard locking open
Half-
sequence
00
Yellow flashing
Invalid state
(safety guard open, guard locking
active)
00
Half-
sequence
Red flashing
(monitoring of the invalid
state)
Safety guard open
00
00
Red
Address 0 or communication dis-
rupted
–
Gray
Dual-channel
independent
Safety guard closed, guard locking
active
Code sequence
Green
Guard locking open
Half-
sequence
00
Red
Invalid state
(safety guard open, guard locking
active)
00
Half-
sequence
Red
(monitoring of the invalid
state)
Safety guard open
00
00
Red
Address 0 or communication dis-
rupted
–
Gray
Dual-channel
dependent
Synchronization
time infinite
∞
Safety guard closed, guard locking
active
Code sequence
Green if safety guard
was previously open
or yellow flashing after
startup if only the guard
locking was open.
Guard locking open
Half-
sequence
00
Yellow flashing if safety
guard was previously
closed.
Red if safety guard was
previously open.
Invalid state
(safety guard open, guard locking
active)
00
Half-
sequence
Yellow flashing if safety
guard was previously
closed.
Red if safety guard was
previously open.
Safety guard open
00
00
Red
Address 0 or communication dis-
rupted
–
Gray