beautypg.com

System status table – EUCHNER CETx-AS-xxx-CB-xxx (Multicode) User Manual

Page 21

background image

Operating Instructions Safety Switch

CET.-AS-...-CB-...

21

System status table

Operating mode

Actuator/door position

LED indicator

output

State

ST

ATE (gr

een)

ST

ATE (r

ed)

Normal operation

closed

Normal operation, door closed and locked

closed

1 x

Normal operation, door closed and not locked

open

1 x

Normal operation, door open

X

5 x

Internal fault (e.g. component faulty, data error)

X

X

X

Internal fault

Key to symbols

LED not illuminated

LED illuminated

10 Hz (8 s)

LED flashes for 8 seconds at 10 Hz

3 x

LED flashes three times

X

Any state

After the cause has been remedied, faults can generally be reset by opening and

closing the door. If the fault is still displayed afterward, use the reset function or

briefly interrupt the power supply. Please contact the manufacturer if the fault could

not be reset after restarting.

Important:

If you do not find the displayed device status in the System status table, this indi-
cates an internal device fault. In this case, you should contact the manufacturer.