beautypg.com

Function, Function of the electronics, Function 6 function of the electronics – EUCHNER CETx-AS-xxx-CB-xxx (Multicode) User Manual

Page 6

background image

Operating Instructions Safety Switch

CET.-AS-...-CB-...

6

Function

Function of the electronics

Safety switches series CET.-AS permit

locking of movable safety guards. They

meet the following safety requirements:

Ì

Category 3, PLe according to EN ISO 13849-1 (mounting head upward)

Ì

Category 4, PLe according to EN ISO 13849-1 (mounting head downward or

horizontal)

The non-contact safety switch CET.-AS consists of three components: coded actua-

tor (transponder), evaluation unit and read head. The evaluation unit is integrated

into the switch housing with the read head.
Each actuator possesses a unique electronic coding and so is a unique element in

the system used. The code in an actuator cannot be reprogrammed.

Unlike systems with unique code detection, on multicode devices a specific code

is not requested but instead it is only checked whether the actuator is of a type

that can be detected by the system (multicode detection). There is no exact com-

parison of the actuator code with the code defined in the safety switch (unique

code detection).

The safety switch with integrated evaluation unit and read head is fastened to the

fixed part of the safety guard.
The actuator attached to the movable part of the safety guard is moved towards

the read head fitted in the safety switch by closing the door. When the switch-on

distance is reached, power is supplied to the actuator by the inductive read head

and data can be transferred.
If the actuator is above the extended lift tappet, the door is closed and the half-

sequence is sent via the AS-Interface bus (state: safety guard closed, guard locking

not active).
The code sequence is sent via the AS-Interface bus when the actuator is inserted

into the recess

(state: safety guard closed, guard locking active).

The bit sequence 0000 is sent via the AS-Interface bus when the safety guard is

opened.

Lift tappet

Slide

Transponder

Spring-
mounted
guard
locking pin

Recess