Configuration in the AS-Interface safety monitor

(see operating instructions for the AS-Interface safety monitor)

Dual-channel dependent

The safety switch is configured in the AS-Interface safety monitor with the AS-

Interface address set as follows, for example:

Ì

dual-channel dependent

Ì

with or without start-up test

Ì

Synchronization time = infinite

In this mode, the safety guard must be opened each time prior to restarting.

Dual-channel conditionally dependent

The safety switch is configured in the AS-Interface safety monitor with the AS-

Interface address set as follows, for example:

Ì

dual-channel conditionally dependent

Ì

independent: In-1

Important:

The switch is monitored for a malfunction; the door message must not switch
before guard lock monitoring. The safety guard does not have to be opened in
this operating mode. Safety is provided again when the guard locking is closed.

Dual-channel independent

The safety switch is configured in the AS-Interface safety monitor with the AS-

Interface address set as follows, for example:

Ì

dual-channel independent

Ì

with or without start-up test

Important:

Failure of a signal or function is not detected in this operating mode. The safety
guard does not have to be opened in this operating mode. Safety is provided
again when the guard locking is closed.