beautypg.com

As-interface status messages – EUCHNER CETx-AS-xxx-CB-xxx (Multicode) User Manual

Page 18

background image

Operating Instructions Safety Switch

CET.-AS-...-CB-...

18

AS-Interface status messages

A dual LED (red/green) displays the colors red, green and yellow. The following

table provides assistance with troubleshooting.

State

LED ASI

Explanation

green

Normal operation

red

No data exchange between master and slave

Cause:

- Master in STOP mode

- Slave not in LPS

- Slave with wrong IO/ID

red/yellow alternately flashing

No data exchange between master and slave

Cause: slave address = 0

red/green alternately flashing

Auxiliary power not connected

or

device fault in the slave.

Contact EUCHNER.

red flashing

Two additional function LEDs may be activated via the AS-Interface bus, e.g. to

display the door status. The LEDs are connected as an output to the AS-Interface

bus via bits D1 and D2.