beautypg.com

Mounting, Mounting 14 – EUCHNER CETx-AS-xxx-CB-xxx (Multicode) User Manual

Page 14

background image

Operating Instructions Safety Switch

CET.-AS-...-CB-...

14

Mounting

Caution!

Safety switches must not be bypassed (bridging of contacts), turned away,
removed or otherwise rendered ineffective.

Ì

On this topic pay attention in particular to the measures for reducing the pos-
sibility of bypassing according to EN 1088:1995.A2:2008, Sec. 5.7.

Ì

The max. achievable category according to EN 13849-1 depends on the instal-
lation position (seeTechnical data page 22).

Caution!

Risk of damage to equipment as a result of incorrect installation.

Ì

Safety switches must not be used as a mechanical end stop. Fit an additional
end stop for the movable part of the safety guard.

Ì

Observe the min. door radii (see figure below).

Ì

Ensure that the actuator contacts the slide in the designated area (see figure
below). Marks on the slide specify the prescribed approach zone.

Ì

The prerequisite for trouble-free long-term operation is protection of the switch
head and the actuator against penetrating foreign objects such as swarf, sand,
and blasting shot, etc. The switch should be installed with the actuating head
down for this purpose.

Ì

Cover the switch and the actuator during painting work.

Figure 2: Door radii and approach zone

74,5 ± 4 mm

Anfahrbereich/

Approach Zone

min R300

min R800