beautypg.com

Fanning timing and delays, Time code events, Linking time code event lists to cue lists – ETC Eos Family v1.9.0 User Manual

Page 16: Creating and editing time code events in live, Time, Eos/ion v1.8, Color encoder page

background image

E T C S u p p l e m e n t

Eos/Ion v1.8

Eos/Ion v1.8 Supplement

Page 16

Electronic Theatre Controls, Inc.

Fanning Timing and Delays

Fanning timing and delays work exactly like fanning parameters.

[1] [Thru] [5] [Time] [6] [Thru] [1] [0] [Enter] - sets the discrete times for channel 1 to 6

seconds, 2 to 7 seconds, 3 to 8 seconds, 4 to 9 seconds, and 5 to 10 seconds.

[1] [Thru] [5] [Delay] [6] [Thru] [8] [Fan]/{Fan} {Mirror} [Enter] - sets the discrete delays of

channel 1 to 8 seconds, 2 to 7 seconds, 3 to 6 seconds, 4 to 7 seconds, and 5 to 8 seconds.

Time Code Events

Linking Time Code Event Lists to Cue Lists

It is possible to link a cue list to a time code event list.

[Cue] [1] [/] {Execute} {TimeCode} [3] [Enter] - links cue list 1 to timecode event list 3. If

there is no timecode event list 3, it will be created as a SMPTE event. If the event list does exist
but isn’t a timecode event, an error will display. Once a cue list is linked to an event list, the
cue list will display the timecode in the external links field for any cue triggered by the
associated event list. This also enables editing the timecode from Live.

[Cue] [1] [/] {Execute} [Enter] or [Cue] [1] [/] {Execute} {TimeCode} [Enter] - will remove

the link.

The cue list display for each cue will display the time of the first event in the linked time code list that
triggers that cue.

Creating and Editing Time Code Events in Live

It is possible to create and edit time code events while in Live.

[Cue] [3] {Execute} {TimeCode} [5][4][5] [Enter] - changes the time of the first event that

fires cue 3 to 5:45.

[Cue] [5] {Execute} {TimeCode} [-] [6] [Enter] - subtracts six frames from the current time.

[+] will add six frames to the current time.

[Cue] [1][0] [Thru] [2][0] {Execute}{TimeCode} [+] [4] - adds four frames to the current time

of each cue within the range. [-] would subtract frames from the current time.

Time

When the [Time] button is pressed on a terminated command line, the selected cue is always
displayed for time modification. To add discrete timing to channels on a terminated command line,
those channels must be reselected.The [Select Last] command can be helpful.

Color Encoder Page

The first page of the color encoder will provide some scroller control, such as frame selection, on
the top encoder. The next three encoders will control HS, CYM, or RGB color mixing. There will be
buttons on the first page for switching between HS, CYM, and RGB. The HS controls will include
buttons for {Brightness to Full}, {Home}, {Min}, and {Max}. The CMY and RGB controls include
buttons for {Home} and {Max} for each of the parameters. No {Min} button will be displayed.