LENTON taper threaded couplers can be

assembled with a standard pipe wrench.

The LENTON inspection wrench, available

from ERICO, may be used to periodically

check tightness (see chart below).

Proper LENTON inspection wrench settings

should be used for the given bar sizes.

Installation:

Step 1 - Remove the bar end protectors, if present, from

the ends of the taper threaded rebar. Visually inspect the

threads to ensure that they are free of concrete, rust or

other debris and are not damaged.

Use a wire brush if threads need to be cleaned.

Step 2 - Inspect part number on the coupler to ensure it is

the proper size for the bar being spliced. (See chart below)

Step 3 - If present, remove cap or internal coupler protector

from the coupler. Visually inspect internal thread to ensure

it is free of concrete or other debris.

Step 4 - Refer to Step 1 above for bar cleanliness. Place

the taper end of the coupler onto the taper threaded bar

and rotate the coupler clockwise until hand tight,

(approx. 4-1/2 turns). If using a standard pipe wrench,

rotate the coupler clockwise to securely tighten the coupler.

The LENTON inspection wrench can be used by an

inspector to periodically check tightness (see chart below

for wrench setting).

* The integrity, torque, and proper installation criteria of the straight threaded connection should be evaluated by a qualified engineer.

TECHNICAL SUPPORT:

www.erico.com

PDF096_G

INSTRUCTION SHEET

1 of 1

CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.

WARNING:

1. ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO

customer service representative.

2. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.

3. All instructions must be completely followed to ensure proper and safe installation and performance.

4. Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death.
The customer is responsible for:

a. Conformance to all governing codes.

b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer.

c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS:

All governing codes and regulations and those required by the job site must be observed.

Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.

LENTON® Bolt Couplers

S4, S5 Series

© 2008,2011,2013,2014 ERICO

International Corporation.

This manual is related to the following products:
Table of contents