beautypg.com

ERICO IP6694 Type MH Connection Rail Transportation PB Series User Manual

Type mh connection rail transportation pb series

background image

Prior to making a connection, read and follow the full instruction sheet IPRNS, the full
instruction sheet IPP, the full instruction sheet shipped with CADWELD (IPX), and
special instructions below.

Strip approximately 1.38” [34.9 mm] of insulation from end of cable

1.

Cut connector as shown above.

2.

Insert stripped cable end into connector. Cable should not extend past center of

3.

hole with insulation butted against connector. If cable is loose in connector, it

should be wrapped with wire to prevent leaks.

Place connector and cable in mold with drilled hole directly under tap hole and

4.

lock with "E-Z" clamp.

Wait approximately 30 seconds until metal has solidified. Open mold and

5.

plunge weld into water to prevent insulation from being damaged by heat.

1.38" [34.9 mm]

.63" [15.9 mm]

1.38" [34.9 mm]

Cable Centered

Under Tap Hole

Strip Cable as Indicated

Tap Hole

Cut Connector as Shown Below

®

CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.

TECHNICAL SUPPORT:

www.erico.com

IP6694_B

INSTRUCTION SHEET

SAFETY INSTRUCTIONS:

All governing codes and regulations and those required by the job site must be observed.

Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.

1 OF 1

© 1995, 2013

ERICO International Corporation

WARNING:

1. ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at

www.erico.com and from your ERICO customer service representative.

2. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.

3. All instructions must be completely followed to ensure proper and safe installation and performance.

4. Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property

damage, serious bodily injury and death.

Type MH Connection

Rail Transportation
PB Series

Table of contents