Enerpac W35000 User Manual
Page 7
7
Fig. F
• Push the release lever (7) back into
the cassette (2). Make sure the ball
detent clicks into place.
Do not operate the tool if the
cassette release lever is not fully
closed.
3.4 To connect the hoses (fig. F)
Make sure all accessories meet
the pressure requirements.
Make sure the quick connect
couplings are securely attached
before operating the tool.
The tool is fitted with male and female
quick-connect couplings. Use Enerpac
twin safety hoses only. Refer to the
table below:
Enerpac hose
model number
Description
THQ-706T
Two hoses, 6 m
(19.5 feet) long
THQ-712T
Two hoses, 12 m
(39 feet) long
• Remove the hose dust caps.
• Connect the hose with the female
coupling (15) to the advance
coupling (4).
• Pull the sleeve on the female
coupling of the hose over the
advance coupling.
• Tighten the sleeve.
• Connect the hose with the male
coupling (16) into the return
coupling (5).
• Pull the sleeve on the return coupling
over the male coupling of the hose.
• Tighten the sleeve.
• Fit the hoses to the pump.
Refer to the pump instruction
manual.
Fig. E
Fig. D