Pump pressure (bar) Torque (Nm)
69
4.745
83
5.708
97
6.671
110 7.565
124 8.528
138 9.491
152 10.453
166 11.416
179 12.310
193 13.273
207 14.236
221 15.199
234 16.093
248 17.055
262 18.018
276 18.981
290 19.944
303 20.838
317 21.801
331 22.764
345 23.726
359 24.689
372 25.583
Pump pressure (bar) Torque (Nm)
386 26.546
400 27.509
414 28.472
428 29.434
441 30.328
455 31.291
469 32.254
483 33.217
497 34.180
510 35.074
524 36.037
538 36.999
552 37.962
566 38.925
579 39.819
593 40.782
607 41.745
621 42.707
634 43.601
648 44.564
662 45.527
676 46.490
690 47.453
7.3 Torque settings - W35000 Series
To set the torque, adjust the pump pressure according to
the following calculation:
Pump pressure = Desired Torque ÷ Torque Factor
Torque Factor (metric system)
W35000 Series
68.772