Enerpac W35000 User Manual
Page 17
17
Pump pressure (psi) Torque (Ft.lbs)
1,000 2,250
1,200 2,700
1,400 3,150
1,600 3,600
1,800 4,050
2,000 4,500
2,200 4,950
2,400 5,400
2,600 5,850
2,800 6,300
3,000 6,750
3,200 7,200
3,400 7,650
3,600 8,100
3,800 8,550
4,000 9,000
4,200 9,450
4,400 9,900
4,600 10,350
4,800 10,800
5,000 11,250
5,200 11,700
5,400 12,150
Pump pressure (psi) Torque (Ft.lbs)
5,600 12,600
5,800 13,050
6,000 13,500
6,200 13,950
6,400 14,400
6,600 14,850
6,800 15,300
7,000 15,750
7,200 16,200
7,400 16,650
7,600 17,100
7,800 17,550
8,000 18,000
8,200 18,450
8,400 18,900
8,600 19,350
8,800 19,800
9,000 20,250
9,200 20,700
9,400 21,150
9,600 21,600
9,800 22,050
10,000 22,500
To set the torque, adjust the pump pressure according to
the following calculation:
Pump pressure = Desired torque ÷ Torque Factor
Torque Factor (imperial system)
W22000 Series
2.25
6.3.2 Imperial system pressure/torque table - W22000 Series