Enerpac W35000 User Manual
Page 23
![background image](/manuals/558489/23/background.png)
23
Pump pressure (psi) Torque (Ft.lbs)
1,000 3,500
1,200 4,200
1,400 4,900
1,600 5,600
1,800 6,300
2,000 7,000
2,200 7,700
2,400 8,400
2,600 9,100
2,800 9,800
3,000 10,500
3,200 11,200
3,400 11,900
3,600 12,600
3,800 13,300
4,000 14,000
4,200 14,700
4,400 15,400
4,600 16,100
4,800 16,800
5,000 17,500
5,200 18,200
5,400 18,900
Pump pressure (psi) Torque (Ft.lbs)
5,600 19,600
5,800 20,300
6,000 21,000
6,200 21,700
6,400 22,400
6,600 23,100
6,800 23,800
7,000 24,500
7,200 25,200
7,400 25,900
7,600 26,600
7,800 27,300
8,000 28,000
8,200 28,700
8,400 29,400
8,600 30,100
8,800 30,800
9,000 31,500
9,200 32,200
9,400 32,900
9,600 33,600
9,800 34,300
10,000 35,000
To set the torque, adjust the pump pressure according to
the following calculation:
Pump pressure = Desired torque ÷ Torque Factor
Torque Factor (imperial system)
W35000 Series
3.5
7.3.2 Imperial system pressure/torque table - W35000 Series