beautypg.com

Enerpac HXD-Series User Manual

Page 11

background image

11

PROBLEM

POSSIBLE CAUSE

1. No pressure

build-up at
wrench, and/or
wrench will not
advance.

A. No power supply or air supply.
B. Pump motor does not rotate

due to wrong voltage supply.

C. Blown out fuses (E-motor)
D. Direction of electric motor

rotation not correct.

E. Couplers at pump and wrench

side not completely
connected.

F. Oil level in pump too low
G. Pressure setting of relief valve

on pump too low.

H. Leakage in pump or wrench.

I. Defective pressure gauge.

J. Incorrectly mounted hoses.

A. Plug in all connections.
B. Check voltage setting

C. Replace fuses.
D. Change wiring of power cable.

E. Depressurize the hoses and

switched off pump, retighten
couplers by hand.

F. Add oil. See pump instructions.
G. Increase pressure by adjusting

pump relief valve. Do not exceed
max. pressure or torque.

H. Determine if leakage is in the

pump or the wrench. Contact your
Enerpac Service Center for
assistance.

I. Connect a second glycerine filled

pressure gauge, adjust pressure on
pump and check both gauge
values.

J. Change hose positions

according to illustration

on

page 7: (P to P) and (T to T).

10

2. Safety valve at

retract side (T) of
wrench opens.

A. Couplers at retract side of

wrench and pump not
completely connected.

B. Incorrectly mounted hoses.

A. When pump is running, switch,

using the remote control, the valve
position from (P or A) to (T or B)
and reverse to depressurize the
system. Switch off the pump and
tighten couplers by hand.

B. Change hose positions

according to illustration

on

page 7: (P to P) and (T to T).

10

3. Hoses can not

be disconnected
from wrench or
pump.

A. Pressure remaining in double-

acting hydraulic system.

B. Hydraulic system too warm.

A. When pump is running, switch,

using the remote control, the valve
position from (P or A) to (T or B)
and reverse to depressurize the
system. Switch off the pump and
disconnect the hoses.

B. Cool the hydraulic system, protect

it against heat and repeat solution
3A above to disconnect hoses.

SOLUTION

7.0 TROUBLESHOOTING
The table below is intended to be used as an
aid in determining if a problem exists.