Built-in protection, Accessories, Status indication – ElmoMC ExtrIQ Digital Servo Drives-Hornet User Manual
Page 55: Automatic procedures

Hornet and Bee Installation Guide
Technical Specifications
MAN-HRBEIG (Ver. 1.304)
55
4.1.7.
Built-In Protection
•
Software error handling
•
Abort (hard stops and soft stops)
•
Status reporting
•
Protection against:
Shorts between motor power outputs
Shorts between motor power outputs and power input/return
Failure of internal power supplies
Over temperature
•
Continuous temperature measurement; temperature can be read on the fly; a
warning can be initiated X degrees before temperature disable is activated.
Over/Under voltage
Loss of feedback
Following error
Current limits
4.1.8.
Accessories
•
External heatsink (Hornet), see Section 3.4.1 for more details.
Catalog number: WHI-HEATSINK-2.
•
Evaluation Board, see Section 3.16 for a picture and more details.
Catalog number: EVA-WHI/GUI/BEL.
•
Cable Kit, see Section 3.16 for more details.
Catalog number: CBL-EVAUNIKIT01.
4.1.9.
Status Indication
•
Output for a bi-color LED
4.1.10. Automatic Procedures
•
Commutation alignment
•
Phase sequencing
•
Current loop offset adjustment
•
Current loop gain tuning
•
Current gain scheduling
•
Velocity loop offset adjustment
•
Velocity gain tuning
•
Velocity gain scheduling
•
Position gain tuning