LO) will then be displayed with or without buzzer

17

.


If a relay board is installed, the comparison results are also sent through the
relay output at the back of this instrument.

Follow the below steps to trigger check weighing mode: -

a. During normal operation (of a function), press [CHECK].
b. The current HI limit is displayed with the Hi symbol on, press [TARE]

to confirm, or

c. Enter a new HI limit through the numeric keys and then press [TARE],
d. Display current LO limit with the Lo symbol on, press [TARE] to

confirm, or

e. Enter a new HI limit through the numeric keys and then press [TARE]
f.

Check weighing function is now enabled. The check is result is shown
by one of the HI/OK/LO symbols,

g. The same result will be sent to the relay output (if ordered) together

with the buzzer signal (if ordered).


NOTE: -
1. For normal comparison, set both HI and LO limits,
2. To check only if result is lower or equal to LO (result

≤ LO?), set HI limit

= 0,

3. To check only if result is higher or equal to HI (result

≥ HI), set LO limit

= 0,

4. To check if result is equal to a specified value, set both HI limit and LO

limit = the specified value

To quit check weighing mode, set both HI and LO limits to zero.

6.11. Quick setting
Press [SET]
to get quick setting parameter ,Press [TARE] to enter and
[CNT] and [UNIT] to shift : PARA,CHECK,ANIMAL,RS232, and
RECHARGE
: To check the currency when charging(mA)
Count : Display the calibration count value, and the parameter set count

value, (press[ZERO]or [TARE] for 3secs to exit)

17

Set CHK Bp to obtain the required buzzer output configuration.