When a container is used, follow the below steps to tare the weight of the
container off to get a net weight result.
a. Remove all loads from platform,
b. Make sure that the ZERO INDICATOR is on. If not, press [ZERO],
c. Place container on platform,
d. Press [TARE] ,
e. TARE INDICATOR appears to indicator tare is in effect and weight
displayed display is net result. To cancel tare effect, remove all loads
from platform and press [TARE] ,
f.
TARE INDICATOR not on. to indicator tare effect has been removed
and weight displayed display is gross result.
6.4.2 Repeated Tare
When M-tare is set to Mode 1, this instrument does not permit multiple tare
operation. Tare effect can only be cancelled when container is removed and
gross weight = zero.
When M-tare is set to Mode 2, this instrument will permit multiple tare
operations provided that both of the below requirements are met: -
a. The tare operation does not permit a reduction of the value of the tare;
b.
The tare effect can only be cancelled when there is no load on the
platform.
6.4.3 Preset Tare
A pre-determined tare weight can be entered via keyboard.
During normal operation, press [PTARE],
enter the pre-determined tare weight through numeric keys ,then press
[TARE]to confirm. This pre-determined tare value will be deducted.
“NET” and “PT” indicator will be shown on
To cancel the preset tare effect, remove all loads from platform then press
[ZERO].
NOTE: -
1.
The pre-determined tare weight entered must be equal to the multiple