beautypg.com

COATS Kit 8114165 Encoder/Sonar Adjustment User Manual

COATS Equipment

background image

8114164 01 12/06

© COPYRIGHT 2005 HENNESSY INDUSTRIES AND COATS ALL RIGHTS RESERVED PRINTED IN U.S.A.

X

XR

R S

Se

erriie

es

s B

Ba

alla

an

nc

ce

err E

En

nc

co

od

de

err//S

So

on

na

arr

A

Ad

djju

us

sttm

me

en

ntt K

Kiitt 8

81

11

14

41

16

65

5

COATS, Inc. • Hennessy Industries • 1601 J.P. Hennessy Drive, LaVergne, TN 37086-3565

(800) 688-6359 • (615) 641-7533 • (615) 641-5104 FAX • www.ammcoats.com

This instruction addresses Errors 55, 57, or 59 that

occur when the value read by the sonar is insufficent
to obtain a correct runout measurement.

1. Make sure the Radial Runout and Lateral Runout

Sonars are aligned correctly.

2. Set Encoder to pulley gap at 0.040”.

3. Go to Self-Test Screen (Green Screen) and verify

that the Encoder is operating correctly and the Sonar is
reading correctly. Use the Sonar check tool (p/n
8114165) or a tape measure and flat card for a target.

XR Model Sonar

4-in Value 14-in Value
Range

Range

1800/1850

Width (Hood

2450-2470

8100-8300

mounted, p/n
801800901)

1800/1850

*Radial Runout

3105-3135

8100-8300

(Rear mouted,
p/n 801801331)

1800/1850

Lateral (Front

2450-2470

8100-8300

mounted, p/n
801801261)

1750

Width (Hood

3840-3880

12800-13200

mounted, p/n
801800901)

Closest Target (Sonar) Reading

Farthest Target (Sonar) Reading

4. For XR 1800/1850 software (version 1.06 and

higher) and XR 1750 software (all versions):

From the Green Screen press button 2 for 2 seconds

and then the Encoder Test Screen will appear.

5. With hood down Press START to run the Encoder

Test. It will work with or without a wheel on the
machine. At the end of the Test Run lines of text will
appear below the graphs:

Line 1: > No. ck encoder: ENCA=64 ENCB=64

Both of these values should be 64, if not, an IN or

OUT encoder adjustment (from the 0.040” gap) is indi-
cated.

Line 2:

XR 1800/1850 Models
> Timing signal: ENCA=2000-3500

ENCB=3500-5000

XR 1750 Model
> Timing signal: ENCA=1500-3000

ENCB=2500-4000

(These numbers will vary within the range and some

even outside of the range. The important thing is to get
rid of Line 3: Error reset.)

If the encoder is not set correctly, a third line of text

will appear:

Line 3: > Error reset ENCA or Error reset ENCB

(If one of the above messages appear: Slightly loosen

the small nuts holding the encoder PCB to the bracket.
For ENCA rotate the PCB slightly upward and for ENCB
rotate the PCB slightly downward. Then re-tighten the
small nuts and rerun the Encoder Test.

Rotate the PCB until the Error reset messages are

eliminated.

6. Now, if any Error 55, 57, or 59 appears then the

problem is most likely a very rough tread pattern or
alignment of the sonar. Move the sonar to a different
spot near the center of the tread.