Table 5 Modbus Holding Registers (continued)
Address Size
Type Value
Description
Values
1589 2
Float
ALARM_CRIT_VF_
QUAL_<
Min VF Quality threshold for critical alarm.
1591 2
Float
ALARM_CRIT_SOS
_QUAL_<
Min SOS Quality threshold for critical alarm.
1593
2
Float
ALARM_CRIT_VF_<
Min Vortical Flow Rate threshold for critical alarm in %.
1595 2
Float
ALARM_CRIT_VF_>
Max
Vortical
Flow
Rate threshold for critical alarm in %.
1597 2
Float
ALARM_CRIT_GVF
_<
Min Gas Volume Fraction threshold for critical alarm in
%.
1599 2
Float
ALARM_CRIT_GVF
_>
Max Gas Volume Fraction threshold for critical alarm in
%.
2001 1
Short
IDLE_TIMEOUT_SE
C
Set communications idle timeout in seconds.
2002 1
Short
ETHERNET_IDLE_T
IMEOUT
Set Ethernet communications idle timeout in seconds.
2003
1
Short
CONTRAST
Set front panel LCD display contrast.
2004
1
Short
STORAGE_ID_0
ID of available values to be saved in storage mode.
2005
1
Short
STORAGE_ID_1
ID of available values to be saved in storage mode.
2006
1
Short
STORAGE_ID_2
ID of available values to be saved in storage mode.
2007
1
Short
STORAGE_ID_3
ID of available values to be saved in storage mode.
2008
1
Short
STORAGE_ID_4
ID of available values to be saved in storage mode.
2009
1
Short
STORAGE_ID_5
ID of available values to be saved in storage mode.
2010
1
Short
STORAGE_ID_6
ID of available values to be saved in storage mode.
2501 2
Long
MAX_SENSOR_TH
RESH
Sets maximum threshold for sensor health diagnostics
(in A/D counts).
2503 2
Long
MIN_SENSOR_THR
ESH
Sets minimum threshold for sensor health diagnostics (in
A/D counts).
2505 2
Long
STORAGE_INTERV
AL
Time in seconds between storage writes.
2507
2
Long
STORAGE_ADDR_1 Address in rabbit controller memory to save to storage.
2509
2
Long
STORAGE_ADDR_2 Address in rabbit controller memory to save to storage.
3001 2
Float
VF_LOW_FILTER_D
ELTA_ARRAY_01
Delta Filter definition for VF.
20959-01 Rev 02