4 transmitter modbus supported function codes, Transmitter modbus supported function codes -3, Table 1 – CiDRA Passive Sonar Transmitters User Manual
Page 13: Supported modbus function codes -3, Table 2, Non-supported modbus function codes -3

2.4
Transmitter MODBUS Supported Function Codes
The transmitter supports these MODBUS Function Codes:
Code Sub
Code Function
01
Read
Coils
02
Read Discrete Inputs
03
Read holding Registers
04
Read Input Registers
05
Write Single Coil
06
Write Single Registers
07
Read Exception Status (Serial only)
08
Diagnostics (Serial only)
08
00
Return Query Data
08
01
Restart Communications Option
08 02
Return
Diagnostic
Register
08
03
Change ASCII Input Delimiter
08
04
Force Listen Only Mode
08
10
Clear Counters and Diagnostic Register
08
11
Return Bus Message Count
08
12
Return Bus Communications Error Count
08
13
Return Bus Exception Error Count
08
14
Return Slave Message Count
08
15
Return Slave No Response Count
08
16
Return Slave NAK Count
08
17
Return Slave Busy Count
08
18
Return Bus Character Overrun Count
08
20
Clear Overrun Counter and Flag
11
Get Communications Event Counter (Serial only)
12
Get Communications Event Log (Serial only)
15
Write Multiple Coils
16
Write Multiple Registers
17
Report Slave ID (Serial only)
22
Mask Write register
23
Read/Write Multiple registers
43 14
Read
Device
Identification
Table 1
Supported Modbus Function Codes
The transmitter does NOT support these MODBUS Function Codes:
Code Sub
Code Function
20
Read File Record
21
Write
File
Record
24
Read FIFO Queue
Table 2
Non-Supported Modbus Function Codes
20959-01 Rev 02
Page 2-3