Water connections, Chemical provisions drain connections – CHAMPION PP3 User Manual

Page 12

background image

4

Installation

Water Connections

! ATTENTION !

A qualified plumber must connect the water supply to the sink in accordance with all

local plumbing and sanitation codes and regulations.

Improper installation will not be covered by the Limited Warranty.

1. HOT WATER

— 3/4" NPT, 120°F/49°C maximum temperature, with a recommended

minimum incoming flowing pressure of 45 PSI measured at the sink.

COLD WATER

— 3/4" NPT, 75°F/24°C maximum temperature, with a recommended

minimum incoming flowing pressure of 45 PSI measured at the sink.

2. A water hardness of 3 grains/gal (US) [51.3 mg/L] or less is recommended.
3. A manual shut-off valve, 3/4" or larger, should be installed in the hot and cold water

supply line as close to the sink as possible for servicing.

Sink Faucets

1. HOT WATER

— 1/2" NPT, (minimum 115°F/46°C, maximum 125°F/52°C) temperature,

with a recommended minimum incoming flowing pressure of 45 PSI measured at the sink.

COLD WATER

— 1/2" NPT, 75°F/24°C maximum temperature, with a recommended

minimum incoming flowing pressure of 45 PSI measured at the sink.

2. A water hardness of 3 grains/gal (US) [51.3 mg/L] or less is recommended.
3. A manual shut-off valve, 1/2" or larger, should be installed in the hot and cold water

supply line as close to the sink as possible for servicing.

Pre-rinse Sprayer

NOTE:

The sink does not have chemical connection electrical provisions.

Contact your local chemical supplier for the chemicals, and dispensers designed for powered

wash sinks.

Chemical Provisions

Drain Connections

1. Sink Drains — 2" NPT
2. Scrapper Drain — 1-1/2" NPT

1. Wash Tank Detergent — Non-sudsing, safe for hands, aluminum safe.
2. Sanitizer — Contact your local chemical supplier for an approved chemical.