3
Installation
Electrical Connections
WARNING
:
Electrocution or serious injury may result when working on an
energized circuit.
Disconnect power at the main breaker or service disconnect switch
before working on the circuit.
Lock-out and tag the breaker to indicate that work is being performed
on the circuit.
! ATTENTION !
A qualified electrician must connect the main incoming power to the sink in accordance with all
local codes and regulations or in the absence of local codes in accordance with the National
Electrical Code or the Canadian Electrical Code. Improper installation will not be covered by the
Limited Warranty.
1. Make sure the incoming power is disconnected at the main disconnect
switch or circuit breaker.
2. The sink is available for either single or three phase operation. Standard
voltages are 208-240V/60/1 & 3, and 480V/60/3.
3. A Machine Electrical Connection Data Plate is located in proximity to the
input terminal block. Make sure the incoming power supply matches the
machine electrical connection data plate before connecting the incoming
power.
4. Remove the fasteners on the front of the control cabinet and lower the hinged
panel.
5. Connect rigid or flexible conduit to the control cabinet through the supplied
access hole in the rear.
6. Connect the power wires to the gray input terminal blocks and the ground
wire to the green input terminal block.
7. Close the control cabinet.
Connecting Incoming Power Supply
Control
Cabinet
L-R machine shown