beautypg.com

CHAMPION IUH351 User Manual

Page 10

background image

4

Installation

Water Connections

1. All models have a 6 ft. flexible hot water fill hose with a 3/4" NPS connector.
2. A 1/2" or larger main incoming supply line should be installed to the dishwasher.
3. A 1/2" or larger shut-off valve should be installed in the water supply line as close to the

dishwasher as possible for service.

4. The pressure regulating valve, PRV,

must be installed after the shut-off service valve if the

incoming flow pressure exceeds

20-22 psi.

5. The hot water supply must provide a minimum of 140°F/60°C, measured at the dishwasher for

the 40°F/ 22°C rise booster.

NOTE

Plumbing connections must comply with local plumbing and sanitary codes.

IMPORTANT

Make sure that the flexible water supply and drain hoses are not kinked.

Drain Connections

1. The dishwasher has a 6 ft. flexible hot water fill hose with a 3/4" NPS connector.
2. The machine is a gravity drain.
3. The maximum drain flow is 8 U.S. gpm /30 LPM.
4. Make sure the drain hose does not kink. Kinks will prevent the dishwasher from draining

completely causing water to flow out the front door.