Troubleshooting – CHAMPION EUCCW Series User Manual
Page 27
19
CONDITION
CAUSE
SOLUTION
A single pump will not run
Motor overload tripped ....................... Reset overload in control cabinet
Defective motor
Contact your service agency
Low or no water
Main water supply is turned off .......... Turn on house water supply
Drain valves are open.......................... Close all drain valves
Doors are not fully closed ................... Close doors
Faulty fill valve ................................... Contact your service agency
Stuck or defective float switch............ Free float /Contact service agency
Cross-flow piping misadjusted/
clogged ................................................ Adjust cross-flow setting/Clean piping
Clogged strainer at supply
connection ........................................... Clean strainer screen
PRV misadjusted or defective............. Readjust pressure setting or replace PRV
Continuous water filling
Stuck or defective float switch............ Free float/Contact service agency
Fill valve will not close.......................
Clean valve,repair or replace valve
Drain valves open................................ Close drain valves
Wash/Rinse tank
Incoming water temp.
Raise incoming temperatureis low
temperature low
at machine low..................................... 140°F minimum for 40°F rise booster
110°F minimum for 70°F rise booster
180° F minimum without booster
Defective thermometer ........................ Check or replace
Defective thermostat ........................... Readjust setting or replace
Defective electric heater element ........ Check or replace
Low steam pressure or volume ........... Check steam supply pressure
Defective steam trap............................ Check or replace
Defective solenoid valve ..................... Check or replace
Prewash tank temperature
Incoming cold water temperature
Lower incoming water temperature
is too high (Optional Cold
too high................................................ to maximum of 65°F
Water thermostat Only)
Defective cold water thermostat ......... Check or replace
Insufficient pumped spray
Clogged pump intake screen ............... Clean
pressure
Clogged spray pipe.............................. Clean
Scrap screen full .................................. Must be kept clean and in place
Low water level in tank
Check drain valves
Pump motor rotation incorrect ............ Reverse wires L1 and L2 in control cabinet
Defective pump seal ............................ Contact service agency
Insufficient final rinse or
Faulty pressure reducing valve
no final rinse
(PRV) .................................................. Clean or replace
Improper setting on PRV .................... Set Flow pressure to 20-22 PSI
Clogged rinse nozzle or pipe .............. Clean
Improper water line size...................... Installer must change to proper size
Clogged “Y” strainer........................... Clean or replace
Troubleshooting
Troubleshooting