Carlin 601GAS Inst Manual User Manual
Carlin Equipment
Contents
PLEASE read this first.......................................................... 3
Codes and standards........................................................... 3
601GAS burner at-a-glance................................................ 4
Prepare site • prepare burner • mount burner .............. 6
Install gas piping ................................................................ 13
Wire burner ......................................................................... 14
Check system • start-up burner/appliance .................. 16
Perform checkout procedures • fill out certificate .... 18
Maintenance and service procedures ........................... 20
Troubleshooting .................................................................. 21
Dimensions and mounting information .......................... 23
Replacement parts............................................................. 24
Instruction manual
Ratings
Input:
..............................................700,000 to 1,500,000 Btuh
Fuels:
.........................................Natural gas or propane gas
Max. supply pressure ..........................14 inches w.c.
Min. supply pressure .............................5 inches w.c.
Manifold pressure ..............................3.5 inches w.c.
Electrical: Power ...........................................120V/60 Hz/1-Phase
Motor... Marathon PSC 1/2 HP, 3450 RPM, 8.4 amps
Total Current ...................Approx. less than 10 amps
Ignition:
........................Carlin Model 41000 solid state ignitor
Control:
........ Carlin Model 60200FR microprocessor control
Agencies: ..........................................................................UL Listed
Installer/servicer — Except where specifically
stated otherwise, this manual must be used only by a
quali-
fied service technician. (In the state of Massachusetts, this
product must be installed by a licensed Plumber or Gas Fitter.)
Failure to comply with this or other requirements in this manual
could result in severe personal injury, death or substantial
property damage.
User — Refer only to User’s Information booklet for
information regarding operation of this burner. The burner
Instruction Manual is intended only for your service techni-
cian. The burner and heat exchanger must be inspected and
started at least annually by your service technician.
™
70 Maple Street
East Longmeadow, MA 01028
Ph 413-525-7700
Fx 413-525-8306
Carlin Combustion Technology, Inc.
T
ech
support
800-989-2275
carlincombustion.com
©
Copyright 2008 — Carlin Combustion Technology, Inc.