Carlin EZ-1/2/3 User Manual
Carlin Equipment
Instruction manual
™
Contents
PLEASE read this first.............................................................. 2
Codes and standards............................................................... 2
EZ-1/2/3 application information............................................ 3
Prepare site • assemble burner • mount burner ................... 5
Prepare burner....................................................................... 10
Wire burner • start burner — 48245 primary control ......... 14
Wire burner • start burner — 40200/42230 primary .......... 16
Wire burner • start burner — 50200 primary control ......... 18
Wire burner • start burner — 60200 primary control ......... 20
Adjustment and verification .................................................. 22
Annual start-up and service .................................................. 23
Repair parts ........................................................................... 24
Maintenance procedures ...................................................... 26
Limited warranty ................................................................... 27
User care and maintenance .....................................Rear cover
...................................................................................................
70 Maple Street
East Longmeadow, MA 01028
Ph 413-525-7700
Fx 413-525-8306
Carlin Combustion Technology, Inc.
T
ech
su p p ort
800-989-2275
carlincombustion.com
©
Copyright 2011 — Carlin Combustion Technology, Inc.
Installer/servicer — Except where specifically
stated otherwise, this manual must be used only by a quali-
fied service technician. Failure to comply with this or other
requirements in this manual could result in severe personal
injury, death or substantial property damage.
User — The burner Instruction Manual is intended only
for your service technician. The burner and heat exchanger
must be inspected and started at least annually by your service
technician.
Ratings
Input:
EZ-1, EZ-1-HP ........................................0.50 to 1.65 GPH
EZ-2, EZ-2-HP ....................................... 1.50 to 2.25 GPH
EZ-3, EZ-3-HP ....................................... 2.00 to 2.60 GPH
Fuels:
.......................... No. 1 or No. 2 heating oil (ASTM D396)
Fuel unit:
...............................................................................Suntec
EZ-1,-2 or -3.................................. 100
psig
nozzle
pressure
EZ-1,-2 or -3-HP ....................Over 100
psig
nozzle
pressure
Electrical: Power .................................................120V/60
hz
/1-
phase
Motor...................................Carlin PSC, 1/6
hp
, 3450
rpm
Current................................................... Approx. 2.5
amps
Ignition:
............... Carlin Model 41000 electronic — 14,000
volts
Control:
........................... U.L. Group I or II primary safety control
Agencies: ...............................................UL Listed (US and Canada)