Installation Procedure:

Set the tool tension to -0-.

1.

Back-out set screw (M54587) and cap screw

2.

(A02887) - Figure 1.

Reposition/replace blade, but do not fully tighten

3.

screws yet.

Squeeze the handle completely and firmly strike the

4.

tension lever against a non-metal surface to actuate

the knife - Figure 2 (note: you may also press firmly on

the tension lever to actuate the knife - Figure 3).

Tools Required:

Hex Keys: 1/16", 7/64"

Parts May Be Required:

Blade: K93987

Cap Screw: M54587

Set Screw: A02887

Special Instructions:

It is critical the knife and blade be assembled with a zero-gap to ensure

clean cut-off. Once correctly positioned, use threadlocking compound

to prevent parts from shifting during use (allow sufficient time for

compound to cure).

Figure 1

Figure 4

Figure 2

Figure 3

The knife is now in the downward position - Figure 4.

5.

K50289

Ball-Lok / Self-Lok Tool

www. BAND-IT-IDEX.com

BAND-IT-IDEX, Inc.

A Unit of IDEX Corporation

4799 Dahlia Street

Denver, CO 80216-3070 USA

P: 1-800-525-0758

F: 1-800-624-3925

Document # K50250 rev. D

Copyright

BAND-IT-IDEX, Inc. 2009

All rights reserved

Page 4 of 5

Blade Installation

Procedure

Set Screw

Cap Screw

Set Screw