• DST Specifications (continued)
DST-9421
Application
Dry stable
Environments
Operating Range (ft.)
0.5 to 35
Enclosure
PC/PET
Transducer Type
Electrostatic
Transducer Material
Gold-Kapton
Ratings
NEMA 12
Approvals
n/a
Operating Temp
-40 to 70ºC
Internal Temp Comp.
Yes
Accuracy
0.25% of range
Dimensions L x D (in.)
5.5 x 2.5
Beam Pattern
9° off axis
Cable
2-conductor
AutoSense SOFTWARE ~The AutoSense software is a built-in feature available
with the DST sensor models listed above. It provides automatic sensitivity
adjustment and is preferable in tank and level applications. Please use the above
part numbers when ordering a DST with the AutoSense option.