Extended Range
Modes 43 - 44 allows the DCR to display ranges greater than 50 ft. These
modes are enabled only in DST’s with extended range.
MODE
DESCRIPTION
PARAMETERS
EXPLANATION
43
Range
Range = 0,1
Some DSTs will allow a
Selection
0 = 1 - 35 ft. Range
detection range of up to
1 = 1 - 72 ft. Range
72 ft. This parameter
Default = 0
enables the DCR to
display that distance.
44
Maximum
Range = 1 - 72 ft.
This parameter works
Range
Default = 35 ft.
only with 72 ft. DSTs and
enables the user to limit
the maximum distance.
AutoSense
Modes 45 disables or enables the AutoSense feature on selected models.
MODE
DESCRIPTION
PARAMETERS
EXPLANATION
45
AutoSense
Range 0,1
Sensors with the extended
0 = OFF
range software can have
1 = ON
the AutoSense feature
Default = 0
disabled or enabled.