2N SmartGate - User Manual User Manual
Page 31

26
Busy tone detection
Set number of busy tone periods for detection of call disconnection from your
PBX. The "0" setting disables busy tone detection.
Setting options: 0-255
Step:
1
Default setting: 4
Continuous tone detection [ms]
Set duration of constant frequency continuous tone for detection of call
disconnection from your PBX. The "0" setting disables continuous tone detection.
Setting options: 0-8900 ms
Step:
35 ms
Default setting: 2030 ms
BabyCall number
If SmartGate is programmed as FXO gateway, parameter defines a number to be
dialed for the automatic call function. If this item is blank, the function is disabled.
Setting options: 0-20 characters (0-9,*,#,+)
Default setting: blank
BabyCall timeout [s]
If SmartGate is programmed as FXO gateway, parameter defines time between
line Off-Hook and automatic call beginning (if enabled). During this timeout
SmartGate waits for dialing that cancels the automatic call. You can make
standard call if the BabyCall function is enabled.
Setting options: 0-255 s
Setting step:
1 s
Default setting: 0 s
Transmission volume
Volume setting for GSM transmission with a 4 dB step. Setting is common for
both FXS and FXO interfaces.
Default setting: medium volume level
Reception volume
Volume setting for GSM reception with a 4 dB step. Setting is common for both
FXS and FXO interfaces.
Default setting: medium volume level