beautypg.com

2N SmartGate - User Manual User Manual

Page 29

background image

24

BabyCall number

A number to be dialed for the automatic call function. If this item is blank, the
function is disabled.

Setting options: 0-20 characters (0-9,*,#,+)
Default setting: blank


BabyCall timeout [s]

Time between line Off-Hook and automatic call beginning (if enabled). During this
timeout SmartGate waits for dialing that cancels the automatic call. You can
make standard call if the BabyCall function is enabled.
Setting options: 0-255 s

Setting step:

1 s

Default setting: 0 s


Transmission volume

Volume setting for GSM transmission with a 4 dB step. Setting is common for
both FXS and FXO interfaces.
Default setting: medium volume level


Reception volume

Volume setting for GSM reception with a 4 dB step. Setting is common for both
FXS and FXO interfaces.

Default setting: medium volume level



8.2.2. Telephone interface FXO parameters


Number of rings before Off-Hook

If SmartGate is programmed as FXO gateway, parameter sets the count of rings
before Off-Hook.
Setting options: 1-255
Step:

1

Default setting: 1


Time for dialing start

If SmartGate is programmed as FXO gateway, parameter defines timeout for first
dialing digit. After timeout SmartGate hangs up the line.
Setting options: 1-255 s

Step:

1 s

Default setting: 15 s


Timeout for dialing end recognize [s]

If SmartGate is programmed as FXO gateway, parameter defines timeout during
which SmartGate waits for further digits to be dialed. It starts to establish
connection when this timeout passes.

Setting options: 1-255 s

Setting step:

1 s

Default setting: 5 s