Lubrication chart -9, Lubrication, Engines – JLG 600SC_660SJC ANSI Service Manual User Manual
Page 21
SECTION 1 - SPECIFICATIONS
3120794
– JLG Lift –
1-9
Table 1-9. Lubrication Chart
Components
Number/Type
Lube Points
Capacity
Lube
Interval
Hours
Comments
3 Months
150 hrs
6 Months
300 hrs
1 Year
600 hrs
2 Years
1200 hrs
Lubrication
1
Swing Bearing
2 Grease Fittings
A/R
MPG
X
Remote Access
2
Swing Drive Hub
Level/Fill Plug
17 oz. (1/2 Full)
EPGL
X
Check level every 150 hrs/change 1200 hours
3
Final Drive Hub
Level/Fill Plug
2.1 gal. (1/2 Full)
EPGL
X
Check level every 150 hrs/change 1200 hours
4
Hydraulic Return Filter
N/A
N/A
N/A
X
Change after first 50 hrs. and every 300 hrs.
thereafter or as indicated by Condition Indica-
tor.
5
Hydraulic Charge Filter
N/A
N/A
N/A
X
Change after first 50 hrs. and every 300 hrs.
thereafter or as indicated by Condition Indica-
tor.
6
Hydraulic Oil
Fill Cap
30.6 gal. Tank
32.7 gal. System
HO
X
Check level daily/change 1200 hours
7
Suction Strainers (in
tank)
2
N/A
N/A
X
Remove and clean at time of hydraulic oil
change.
Engines
8
Oil Change w/Filter -
Deutz
Fill Cap/Spin-on Element
11 Quarts Crankcase
**5 Quarts Cooler
EO
X
Check level daily/Change every 1000 hours
or one year, whichever comes first. Adjust
final oil level by mark on dipstick.
9
Fuel Filter - Deutz
Replaceable Element
N/A
N/A
X
10
Air Filter - Deutz
Replaceable Element
N/A
N/A
X
Or as indicated by Condition Indicator.
NOTES:
KEY TO LUBRICANTS
Lubrication intervals are based on machine operation under normal
conditions. For machines used in multi shift operations and/or
exposed to hostile environments or conditions, lubrication frequen-
cies must be increased accordingly.
** When changing oil in the Deutz oil cooled engine, drain both the crankcase and
the cooler. When refilling it is acceptable to overfill the crankcase (16 qts., capac-
ity of both crankcase and cooler combined). Start engine, allow the engine to run
until the thermostat opens (approximately 221 degrees F) cooler will fill up within
minutes; shut down and wait for approximately two minutes. Check oil level, fill oil
to max marking on the dipstick.
EO
EPGL
HO
MPG
Engine Oil
Extreme Pressure Gear Lube
Hydraulic Fluid (Mobil #424 or equivalent)
Multi-Purpose Grease