3 performance data, Turning radius (outside), Turning radius (inside) – JLG 600SC_660SJC ANSI Service Manual User Manual
Page 14: Boom elevation, Machine weight approximately, Machine height (stowed), Machine length (stowed), Machine width, 4 function speeds, Machine orientation when doing speed tests
SECTION 1 - SPECIFICATIONS
1-2
– JLG Lift –
3120794
1.3
PERFORMANCE DATA
Travel Speed
1.6 MPH (2.6 Km/hr.)
Travel Speed - Out of Transport
0.4 MPH (0.6 Km/hr.)
Gradeability.
55%
Turning Radius (Outside)
8 ft. (2.4 m)
Turning Radius (Inside)
0
Boom Elevation
600SC - +60 ft. 2 13/16 in. (18.36 m)
-6 ft. 1 11/16 in. (1.87 m)
600SCJ - +60 ft. 5 3/4 in. (18.43 m)
-9 ft. 9 3/16 in. (2.98 m)
660SCJ - +66 ft. 7 5/8 in. (20.31 m)
-11 ft. 5 1/4 in. (3.49 m)
Machine Weight approximately
Steel Track - 25,900 lbs. (11,748 kg)
Rubber Track - 26,860 lbs. (12,184 kg)
Machine Height (Stowed)
Steel Track - 8’4" (2.54 m)
Rubber Track - 8’6" (2.59 m)
Machine Length (Stowed)
35’ 6" (10.8 m)
Machine Width
8 ft. (2.4 m)
1.4
FUNCTION SPEEDS
Machine Orientation When Doing Speed
Tests
Lift: Telescope Retracted. Lift Up, Record Time, Lift Down,
Record Time.
Swing: Boom at Full Elevation. Telescope Retracted.
Swing the Turntable off center and stop. Swing the oppo-
site direction ana start the test wen the turntable is cen-
tered up. This eliminates ramp up and down on the
controller affecting times.
Telescope: Boom at Full Elevation; Telescope Retracted;
Telescope Out, Record Time. Telescope In, Record Time.
Tracking: Test to be done on a gravelled level surface.
Position the machine driving at high speed at a reference
point. (No steer correction). Results should be 4 to 6
ft.(1.2 to 1.8 m) tracking error at 200 ft. (60.9 m).
Drive: Test should be done on a graveled level surface.
Drive select switch should be set at High Speed. Start
approx. 10 ft. from starting point so that the unit is at max-
imum speed when starting the test. Results should be
recorded for a 200 ft. (60.9 m) course. Drive Forward,
Record Time. Drive Reverse, Record Time.
Drive (Out of Transport): Test should be done on a grav-
eled level surface. Drive select switch should be set at
Low Engine, Low Drive (The platform speed knob control,
if equipped, could be selected to the creep speed to simu-
late the boom above horizontal). Results should be
recorded for a 50 ft. (15.2 m) course. Drive Forward,
Record Time. Drive Reverse, Record Time.
Table 1-1. Function Speeds (In Seconds)
Function
Speed
Lift Up
46-60
Lift Down
33-43
Swing Right & Left*
79-101
Telescope In
22-33
Telescope Out
50-67
Platform Rotate Right & Left**
16-25
Jib Up
22-34
Jib Down
16-26
Drive (Forward & Reverse)
85-90
Drive Out of Transport (Forward & Reverse)
80-85
*Max 10% Difference Between Left & Right