Chapter 11 – Troubleshooting

56

AB60J – 0182099EE

Symptom

Hydraulic fluid temperature 93°C

(200°F ) or more.

Severe hydraulic leak.

Possible Cause

Prolonged boom operation or driving.

High pressure fluid return to reservoir

caused by kinked or twisted hose.

Hydraulic system component failure.

Failure of hose, tube, fitting, seal, etc.

Corrective Action

Stop operation until fluid cools.

Remove the kink or twist from the

hose. Let fluid cool before resuming

operation.

Stow the machine and do not operate

until repairs are made.

Do not operate machine until repairs

are made.