beautypg.com

Chapter 4 – safety devices, Warning – Snorkel AB60J CE User Manual

Page 15

background image

AB60J – 0182099EE

11

At the upper controls, the emergency stop is a two-posi-

tion push button (refer to Figure 4.2). Push the emer-

gency stop button in to disconnect power to the upper

control circuits. Pull the button out to restore power.

Figure 4.2 – Upper Controls

Emergency Power System

The emergency power system includes a back-up pump,

motor, and battery. Use this system to operate the boom

and turntable functions to lower the platform if the main

power system fails due to engine or pump failure. Hold

the engine/emergency power switch (refer to Figure 4.1

and 4.2) down to activate the emergency power sys-

tem.

The length of time the pump can be operated depends

on the capacity of the battery.

Emergency Lowering Knobs

The emergency lowering knobs may be used to lower

the booms if the engine will not start and the emergency

power system will not work. There is a knob to lower the

riser boom and one to lower the main boom. The riser

boom knob (refer to Figure 4.3) is inside the rear of the

turntable.

Figure 4.3 – Riser Boom Emergency

Lowering Knob

Chapter 4 – Safety Devices

Emergency

Stop Button

Ground Operation

Switch

Engine/Emergency

Power Switch

Emergency

Stop Button

Engine/Emergency

Power Switch

Emergency

Lowering Knob

Inside Turntable

This aerial work platform is manufactured with safety

devices, placards, and decals to reduce the likelihood

of an accident. For the safety of all personnel, do not

disable, modify, or ignore any safety device. Safety de-

vices are included in the daily prestart inspection.

A

Warning

The potential for an accident increases when safety

devices do not function properly. Death or serious

injury can result from such accidents. Do not alter,

disable, or override any safety device.

If any safety devices are defective, remove the aerial

platform from service until qualified maintenance per-

sonnel can make repairs.

Emergency Stop Controls

There is an emergency stop control at the lower and

upper controls.

At the lower controls, the emergency stop is a two-posi-

tion push button (refer to Figure 4.1). Push the emer-

gency stop button in to disconnect power to all control

circuits. Pull the button out to restore power.

Figure 4.1 – Lower Controls

Note

The lower controls override the upper controls. If the

upper control emergency stop button is engaged, the

lower controls can still be used to operate the aerial plat-

form.