Chapter 3 – Safety

AB60J – 0182099EE

9

It is best not to transfer from the platform to another

structure or from the structure to the platform, unless

that is the safest way to do the job. Judge each situation

separately taking the work environment into account. If

it is necessary to transfer from the platform to another

structure the following guidelines apply:

1. Where possible, place the platform over a roof or

walking structure to do the transfer.

2. Transfer your anchorage from one structure to the

other before stepping across.

3. Remember that you might be transferring to a struc-

ture where personal fall arrest is required.

4. Use the platform entrance, do not climb over or

through the guardrails.

Do not operate the aerial platform in windy or gusty con-

ditions. Do not add anything to the aerial platform that

will increase the wind loading such as billboards, ban-

ners, flags, etc.

Never operate the aerial platform without all parts of the

guardrail system in place and the gate closed. Make

sure that all protective guards, cowlings, and doors are

securely fastened.

Do not exceed the platform capacity as indicated on the

platform rating placard on the platform. Do not carry loads

that extend beyond the platform guardrails without prior

written consent from Snorkel.

Do not operate the aerial platform from trucks, trailers,

railway cars, floating vessels, scaffolds, or similar equip-

ment unless the application is approved in writing by

Snorkel.

Do not use the aerial platform as a crane, hoist, jack, or

for any purpose other than to position personnel, tools,

and materials.

Do not climb on the guardrails or use ladders, planks, or

other devices to extend or increase the work position

from the platform.

Take care to prevent rope, electrical cords, and hoses,

etc., from becoming caught in or on the aerial platform.

If the platform or booms becomes caught on an adja-

cent structure or other obstacle and is prevented from

normal motion, reverse the control to free the platform.

If control reversal does not free the platform, evacuate

the platform before attempting to free it.

Electrical System

Charge the battery in a well-ventilated area free of flame,

sparks, or other hazards that might cause fire or explo-

sion.

Do not operate any of the aerial platform functions while

the battery charger is plugged in.

A

Warning

Batteries give off hydrogen and oxygen that can

combine explosively. Death or serious injury could

result from a chemical explosion. Do not smoke or

permit open flames or sparks when checking the

batteries.

Battery acid can damage the skin and eyes. Serious

infection or reaction can result if medical treatment

is not given immediately. Wear face and eye protec-

tion when working near the batteries.

Batteries contain sulfuric acid that can damage your eyes

or skin on contact. Wear a face shield, rubber gloves,

and protective clothing when working around batteries.

If acid contacts your eyes, flush immediately with clear

water and get medical attention. If acid contacts your

skin, wash off immediately with clear water.

Hydraulic System

The hydraulic system contains hoses with hydraulic fluid

under pressure.

A

Danger

Hydraulic fluid escaping under pressure can have

enough force to inject fluid into the flesh. Serious

infection or reaction will result if medical treatment

is not given immediately. In case of injury by escap-

ing hydraulic fluid, seek medical attention at once.

Do not place your hand or any part of your body in front

of escaping hydraulic fluid. Use a piece of cardboard or

wood to search for hydraulic leaks.

Engine and Fuel Handling Precautions

Refer to the engine manufacturer’s Operator’s Manual

for complete information on safe engine operation, main-

tenance, and specifications.

A

Danger

Engine exhaust contains carbon monoxide, a poi-

sonous gas that is invisible and odorless. Breath-

ing engine exhaust fumes will cause death or seri-

ous illness. Do not run the engine in an enclosed

area or indoors without adequate ventilation.

Be careful not to run the diesel fuel tank empty. Bleed

the fuel system if air enters the lines between the tank

and the injection pump.

Allow the engine to return to idle before shutting the en-

gine off.

Do not smoke or permit open flames while fueling or

near fueling operations.