24 508159-000

TL49K

5.

Cage Overload


In the event of the cage being overloaded, an audible alarm will sound and

the cage controls will cut out.

To

re-start, enough load must be removed from the cage so that the

alarm stops sounding.


In cases where the overload can not be immediatley removed or the cage

has fouled, then the overload override selector switch can be used to move

the platform to a safe position so that the overload can safely removed.

The Key, Motor Run/Deadman and a Control Lever must be
operated at the same time to effect this action

4. Emergency

Procedure,

Manual Raising of Outriggers.

In the event of power failure, the outriggers can be raised to their transport

position.

First the hand pump hose fitted to port HP1, must be redirected from HP1,

to

port HP2, and the blanking plug from HP2 must be replaced into HP1,

using a 22mm spanner.


Once

connected,

move an Outrigger Control Lever in the required

direction

of

movement, and operate the hand pump. When the Outrigger

starts to raise, continue depressing the control lever.

Some hydraulic oil will be lost during this procedure. This will
still allow Emergency operations, but will need to be replaced
before full normal use can resumed.

!

EMERGENCY CONTROLS