beautypg.com

Snorkel TL49K-sn8500+ User Manual

Page 12

background image

8 508159-000

TL49K

1. DO

NOT operate this machine unless you have been fully trained in its safe

use.

2. DO

NOT operate the machine on soft, slippery or sloping ground unless

adequate precautions have been taken.


The stabilisers are designed to operate on firm level ground with a minimum

bearing strength of 50N/cm

2

.


The maximum load imposed by an outrigger is 12.5kN.


Advice should be obtained from UpRight as to the type of supports and

precautions required before attempting to operate the machine outside

these

parameters.


3. DO

NOT use any equipment in the basket to increase the reach or working

height of the machine, e.g. ladders.


4. DO

NOT fit any additional equipment to the machine that would increase

the wind loading, e.g. notice boards.


5. DO

NOT use the machine for any application that may produce special loads

or forces: the manufacturer, UpRight Powered Access, must be consulted for

approval of special applications prior to use.


6.

DO NOT use the machine close to live electrical conductors. The minimum

safe working distance for a machine working near overhead power cables is
the maximum extended length of the booms plus 15 metres, measured
with the booms pointing towards the lines, i.e. safe working distance for the
TL49K is 24 metres. It is the operator‘s responsibility to ensure that, when

working in the vicinity of live overhead high-voltage lines, the minimum safe
working distance is maintained. Erect a simple barrier tape at the safe
distance.















7.

WORKING CLOSE TO POWER CABLES – if work has to be carried out at less

than the safe working distance, the operator must ensure that the

electricity supply has been switched off. Before commencing work, a

written permit to work must be obtained from the owners of the power

cables or the responsible authority.

15m

26m

15m

24m

WARNING NOTICES