The unit must have a thorough inspection carried out every 6 months

in accordance with LOLER Regulations 1998 and a Certificate of

Thorough Inspection produced by a competent person.

Always ensure the machine structure is in good, sound, undamaged

condition. Any inspection procedure is always aided by keeping

the machine clean. NB. Do not steam clean the battery charger or

electrical components.

!

Daily Checks.

1. Damaged or Loose Fittings.

Visually Inspect the machine for signs of wear and tear, damage, loose or missing

parts.

2. Wheels.

Check tyres are at the correct pressure, TL49J = 76psi (5.25 bar).

3. Hydraulic fluid.

The hydraulic oil tank is located underneath the slew cover on the left hand side of

the machine (looking from the cage end), Ref, Fig.2, section J. With the booms and

outriggers in the transport position, the hydraulic oil level should be visible between the

upper and lower marks of the dipstick.

Do Not Overfill the Tank

Top up with ISO Grade 22 hydraulic oil if necessary.

4. Safety Switches.

Check all limit switch arms are free from damage and move easily outrigger switches.

With outriggers in transport position, it must not be possible to operate the extending

structure.

With outriggers deployed, under load and top or bottom boom raised approximately

50mm, it must

NOT be possible to operate the outrigger controls.

The flick boom is not interlocked with the outriggers.

5. Emergency Stop Switches.

Emergency stop switches must operate correctly. Check that each stops the machine’s

controls and that restarting is prevented until all stop switches are unlatched.