Daily checks – Snorkel TL49J-01-sn008562+ User Manual
Page 31
27
TL49J
513868-000
The unit must have a thorough inspection carried out every 6 months
in accordance with LOLER Regulations 1998 and a Certificate of
Thorough Inspection produced by a competent person.
Always ensure the machine structure is in good, sound, undamaged
condition. Any inspection procedure is always aided by keeping
the machine clean. NB. Do not steam clean the battery charger or
electrical components.
!
Daily Checks.
1. Damaged or Loose Fittings.
Visually Inspect the machine for signs of wear and tear, damage, loose or missing
parts.
2. Wheels.
Check tyres are at the correct pressure, TL49J = 76psi (5.25 bar).
3. Hydraulic fluid.
The hydraulic oil tank is located underneath the slew cover on the left hand side of
the machine (looking from the cage end), Ref, Fig.2, section J. With the booms and
outriggers in the transport position, the hydraulic oil level should be visible between the
upper and lower marks of the dipstick.
Do Not Overfill the Tank
Top up with ISO Grade 22 hydraulic oil if necessary.
4. Safety Switches.
Check all limit switch arms are free from damage and move easily outrigger switches.
With outriggers in transport position, it must not be possible to operate the extending
structure.
With outriggers deployed, under load and top or bottom boom raised approximately
50mm, it must
NOT be possible to operate the outrigger controls.
The flick boom is not interlocked with the outriggers.
5. Emergency Stop Switches.
Emergency stop switches must operate correctly. Check that each stops the machine’s
controls and that restarting is prevented until all stop switches are unlatched.
MAINTENANCE