2. Operation & Specifications
2-16
HOUR METER
To access the hour meter function perform the following steps.
1. Climb into the basket (with the machine powered up)
2. Push the platform emergency stop button.
3. Hold down the following buttons, Horn and Lift.
4. While holding the buttons twist the emergency stop button to return power to the machine.
5. hr.” will now be displayed on the read-out, Pressing the right turn button will scroll through
the accumulated hours two digits at a time. For example, if pressing the right turn button
once dislays “20”, pressing it a 2nd time displays “58”, and pressing it a 3rd time displays
“hr.”, the elapsed time of operation is 2058 hours.
LONG-TERM STORAGE
PRESERVATION
1. Clean and touch up damaged paint surfaces.
2. Fill the hydraulic tank to operating level with the platform fully lowered. Fluid should be
visible on the tank dip stick.
3. Coat exposed portions of cylinder rods with a preservative such as multipurpose grease
and wrap with barrier material.
4. Coat all exposed un-painted metal surfaces with a light oil or other preservative.
5. Cover the machine with tarpaulin if possible. If this is not available it is advisable to cover
the mast and jib mount area as a minimum. This will prevent moisture from entering the
mast, battery and chassis areas.
Figure 3: Battery Disconnect
BATTERIES
1. Disconnect the batteries at the quick connect plug and socket. This is located in the
chassis between the controller and the hydraulic tank.
2. Disconnect the battery leads and tape up the lead terminals to ensure insulation.
Better battery life and efficiency is achieved if the batteries are used consistently. It is
therefore recommended that the batteries are used elsewhere if the machine is to be
unused for an extended period (2 weeks or more).
W A R N I N G
RISK OF SERIOUS INJURY. Take particular care when handling
batteries. Acid spills can cause severe burns or blindness.
DO NOT store batteries close to naked flames or close to steel
fabrication areas.
Battery disconnect
is located behind the
controller