beautypg.com

Danger, Warning – Snorkel AB46JE User Manual

Page 35

background image

Chapter 8 – Prestart Inspection

AB46JE – 0260072

31

Figure 8.14 – Upper Controls

A

Danger

Pinch points may exist between moving components.
Death or serious injury will result from becoming
trapped between components, buildings, structures,
or other obstacles. Make sure all personnel stand
clear of the aerial platform while performing the pre-
start inspection.

A

Warning

The potential for an accident increases when operat-
ing an aerial platform that is damaged or malfunction-
ing. Death or serious injury could result from such
accidents. Do not operate the aerial platform if it is
damaged or malfunctioning.

4. Step down on the platform foot switch.

5. Visually check to make sure the drive fault light is lit

at the lower controls.

If the drive fault light is not lit or fl ashing, repeat

the steps 1 through 5 to ensure the controls are

set up properly.

After ensuring the controls are set up properly

and the drive fault light is not lit or fl ashing, re-

move the aerial platform from service until quali-

fi ed maintenance personnel can make repairs.

6. Test the platform foot switch by moving a boom

function control without stepping on the foot switch.

If movement occurs the interlock is not functioning

properly. Do not operate the machine until the prob-

lem is corrected.

7. Test the operation of each control in both directions

from the upper controls.

8. The drive range switch and maximum travel speeds

are interlocked through limit switches on the riser and

main boom that senses the position of the booms.

When the main boom is raised approximately 1

½

(3.8 cm) or extended approximately 1

(2.5

cm), the machine should travel in low speed

only.

To operate in high speed the booms must be

stowed.

Emergency Stop

To test the emergency stop button from the upper con-

trols:

1. At the lower controls, turn the start switch to the on

position and place the control selector switch in the

upper control position.

2. At the upper controls, push the emergency stop but-

ton inward to turn off electrical power.

3. Verify that the upper control functions do not oper-

ate.

Emergency Power

To test the emergency power system from the upper

controls:

1. Turn the battery disconnect switch on.

2. At the lower controls, pull the emergency stop button

outward and place the start switch in the on position.

Place the control selector switch in the upper control

position.

3. At the upper controls, pull the emergency stop button

outward (refer to Figure 8.14).

4. Hold the emergency power switch in the emergency

power position and step on the platform foot switch

to verify operation of the aerial platform using the

emergency power system.

Horn Switch

Operate the horn switch (refer to Figure 8.14) to ensure

that it sounds to warn personnel in the area.

Electrical Power Outlet

To test the electrical power outlet:

1. Connect a source of 110 volt AC power to the power-

input connector on the right side of the chassis (refer

to Figure 8.15).

Emergency

Power Switch

Emergency

Stop Button

Horn Switch